Agilent Italian version- Cary 60 UV-Vis Specifications Manual

The Agilent Cary 60 is a UV-Vis spectrophotometer produced by Agilent. It uses a classic Cary optical design with a Czerny-Turner monochromator. The spectral range is 190-1100nm, the resolution is less than 1.5nm, and a single xenon light source is used with a lifetime of up to 10 years. It has two silicon detectors, multiple layers of quartz optical elements, a scanning speed of up to 24000nm/min, a maximum speed of 80 points/second for time events, and a grid shift in non-measurement. It is immune to external scattered light and is fully controlled by a PC via Windows and a USB port. It has GLP and CFR 21 Part 11 software for complete instrument validation in accordance with all pharmacopoeias.

File format: PDF Size:66 KB

Agilent Italian version - Consumables Supplies Required for Repair Manual

When your system needs repairs, it’s best to have complete coverage that includes a supply of the spare parts and consumables not covered by basic repair services. That’s why the Agilent Advantage Bronze, Silver and Gold services include the Optional Repair Parts and Consumables. The Optional Repair Parts and Consumables option covers the cost of all replacement parts or consumables needed by the technician to diagnose issues and repair your systems. Since all “Advantage” services also cover travel costs, labor and parts, you can be confident that you’re covered for all your repair costs. You’ll get all original Agilent parts and consumables regardless of the number of repairs or the quantity of products required to return your system to normal operation. Even if you only have one repair, services that include all the spare parts and consumables will easily pay for the difference in price over services that don’t.

File format: PDF Size:75 KB

Agilent Guida alla scelta delle colonne Zorbax Agilent per HPLC Manual

This document mainly introduces the ZORBAX series products, including ZORBAX StableBond, ZORBAX SB-Aq, ZORBAX Rx, ZORBAX Eclipse XDB, ZORBAX Bonus-RP, ZORBAX Extend-C18, other ZORBAX HPLC analytical columns and ZORBAX CombiHT, ZORBAX Rapid Resolution 3.5 µm, MicroBore and Capillary.

File format: PDF Size:19548 KB

Agilent Italian Version - Agilent 7890A Network Gas Chromatograph Data Sheet Manual

The Agilent 7890A Gas Chromatograph is a state-of-the-art gas chromatograph with excellent performance for any application. The outstanding performance is guaranteed by advanced Electronic Pneumatic Control (EPC) modules and extremely precise control of the GC oven temperature. Each EPC unit is optimized for its intended use and equipped with specific injector and detector. The temperature control of the 7890A GC oven allows for fast and precise gradients. The overall thermal performance ensures optimal chromatography with peak symmetry, retention time repeatability, and retention index accuracy. Agilent's Capillary Flow Technology provides a new dimension to chromatography, ensuring reliable and leak-free capillary connections in the oven that can withstand repeated cycles. The 7890A GC features enhanced firmware to expand the capabilities of the innovative capillary flow modules and advanced software to simplify backflush setup and operation. In addition to facilitating the analysis of complex matrices, it offers increased flexibility and reliability.

File format: PDF Size:228 KB

Agilent Pursuit XRs Prep LC column Italian Manual

Pursuit® XRs Prep HPLC Columns are a new type of LC prep column developed by Varian. They are made of high-purity silica gel and have extremely high separation ability, suitable for the separation and purification of various complex samples.

File format: PDF Size:731 KB

Agilent VF-5ht UltiMetal Italian Manual

The VF-5ht UltiMetal is the latest addition to Varian’s popular FactorFour™ series of ultra-low bleed GC columns. FactorFour columns are premium-quality GC columns that offer purge specifications up to four times lower than those of other products on the market. The columns are produced using an exclusive and patented stabilization technology that guarantees maximum signal-to-noise ratio for trace analysis, minimum detector contamination, greater mass spectrum integrity, minimal ion background and faster stabilization. In short, they provide significantly improved chromatographic performance.

File format: PDF Size:104 KB

Agilent Italian version-On Demand Repair Services Update trail-5980-2796ITIT Manual

This article introduces Agilent Technologies' on-site repair services, including repair costs, repair process and repair scope.

File format: PDF Size:69 KB

Agilent OQ/PV Software per ChemStation Agilent Manual

This document describes the OQ/PV services for Agilent ChemStation software, including safety, communication, and internal testing. These services use a written protocol and software qualification procedure to ensure that Agilent ChemStation operates within pre-defined limits, can handle any safety issues, and reports chromatograph results accurately. These services are also available for systems configured solely for data analysis, such as Agilent networked solutions. All tests are fully documented. The documentation attests to the software's compliance with test specifications and can be used as support for FDA 21 CFR Part II certification.

File format: PDF Size:32 KB

Agilent OQ/PV per LC HP 1090 Manual

This document contains the operation and maintenance instructions provided by Agilent Technologies for Hewlett-Packard 1090 Series liquid chromatographs.

File format: PDF Size:34 KB

Agilent OQ/PV cromatografo liquido Agilent Serie 1100 Manual

This document describes Agilent Technologies' OQ/PV procedures for the Agilent 1100 Series Liquid Chromatograph

File format: PDF Size:33 KB

Agilent OQ/PV per LC Serie HP 1050 Manual

This file describes the performance validation and operational qualification procedures for the Hewlett-Packard 1050 Liquid Chromatograph

File format: PDF Size:33 KB

Agilent OQ/PV per GC Agilent 6850 Manual

This document is Agilent Technologies' 6850 GC OQ/PV procedure, which describes how to evaluate the instrument performance and verify if it meets the specification.

File format: PDF Size:39 KB

Agilent OQ/PV per GC Agilent Serie 6890 Manual

This file introduces OQ/PV test methods for Agilent 6890 series gas chromatographs

File format: PDF Size:40 KB

Agilent OQ/PV per gascromatografi Agilent Serie 6890 e 6850 con spazio di testa Manual

This document describes the Operational Qualification/Performance Verification (OQ/PV) procedures of Agilent Technologies for the 6890 series gas chromatograph (GC) with headspace sampler. It explains how to document the correct functioning of the entire system according to established specifications. The OQ/PV procedures use internal tests and analytical methods with certified samples. Typically, the entire OQ/PV procedure can be completed in one day, minimizing downtime and maintaining high productivity. However, the limits described in the document and the online Help system of ChemStation apply to new or repaired instruments according to Agilent specifications. Instruments that have been in daily use for a long time may not comply with Agilent specifications. Acceptance criteria may vary depending on analytical requirements and should be agreed upon with Agilent support services.

File format: PDF Size:39 KB

Agilent Soluzioni di supporto Agilent per la conformità Manual

Agilent Technologies provides a wide range of laboratory and compliance services for Agilent chemical analysis instrumentation. These services provide you with the evidence you need to meet the requirements of regulatory agencies such as the U.S. Food and Drug Administration (FDA) and the Environmental Protection Agency (EPA), the International Organization for Standardization (ISO) and the Organization for Economic Cooperation and Development (OECD). These services can also help you save time and money by eliminating the need for you to develop your own operating procedures for qualifying Agilent instruments and training laboratory personnel. These services can ensure that the instrument is performing according to the manufacturer's specifications. These services can also help you follow the same operating procedures and produce the same documentation from laboratory to laboratory, worldwide. This can help you achieve consistent and traceable results, as well as improve method transfer. These services can help you reduce the risk of financial loss due to non-compliance. These services can ensure reliable measurements, including traceable data and complete documentation, from sample introduction to final report, for you, your customers and regulatory agencies.

File format: PDF Size:363 KB

Agilent Servizi Agilent per l industria chimica e petrolchimica Manual

Agilent offers a wide range of services for the chemical and petrochemical industry, including repair, maintenance, spare parts, training, and on-site support. Agilent's services can help chemical and petrochemical industry customers keep their equipment running smoothly and improve production efficiency.

File format: PDF Size:15 KB

Agilent Introduzione alla cromatografia liquida (H5930A) Manual

This manual introduces how to use the audio functions of TCL 4 series SmartTV.

File format: PDF Size:25 KB

Agilent Introduzione alla gascromatografia capillare (H2615A) Manual

This document introduces the features and characteristics of the ASUS ROG Strix Scar 15 G533QS laptop. This laptop is powered by an Intel Core i7-12700H processor, NVIDIA GeForce RTX 3070 Ti graphics card, 16GB of memory, and a 1TB SSD. It also features a 15.6-inch 1080p display and a 720p webcam.

File format: PDF Size:25 KB

Brands